Product

Dc cross-linked polyethylene insulation material for wires and cables DC-YJ-100

This product is mainly made of low-density polyethylene resin through mixing, plasticizing and granulation. It features excellent electrical performance, physical properties and process fluidity. By suppressing the generation of space charges, it increases the service life of cables and is mainly applied to DC cross-linked polyethylene insulated cables of corresponding voltage levels.

Product details

Performance indicators (typical values):   enforce standards:TICW 7.1-2012  GB/T 31489.1-2015  

Serial number

Test project

Unit 

Indicator

Typical value

1

Tensile strength

MPa

≥16

20

2

Elongation at break

%

≥420

500

3

Air thermal aging

Test conditions


135℃×168h

Rate of change of tensile strength

%

±25

±15

Rate of change in elongation at break

%

±25

±15

4

(-76℃)Impact embrittlement performance

N/A

≤15/30

0/30

5

Thermal extension

200℃,0.2MPa,15min

Elongation under load

%

≤80

60

6

Permanent deformation rate after cooling

%

≤5

2.5

7

Gel content

%

≥80

85

8

Volume resistivity,23℃

Ω.cm

≥1.0×1013

1.0×1014

9

Short-term breakdown strength (smaller plate electrode diameter 25mm, voltage rise rate 500v/s)

Power frequency breakdown strength

MV/m

≥30

33

Dc breakdown strength

MV/m

≥100

110

10

Dielectric constant

/

≤2.5

2.3

11

Water absorption test(85±2℃,336h)

Mg/cm2

≤1

0.8

12

Heat shrinkage test(130±2℃,6 h)

%

≤4.5

4

Application process reference

Region1

Region2

Region3

Region4

Region5

Region6

Region7

Region8

Neck of the machine

Nose of the machine

85℃

105℃

108℃

110℃

112℃

113℃

113℃

113℃

115℃

114℃

Packaging and storage

The product is packed in a waterproof and dustproof PE inner bag, with a hard corrugated carton for shaping and protection, and an additional waterproof film cover. The standard net weight of each box is 500kg or 600kg.

It should be stored in a clean, dry and well-ventilated environment, with an appropriate storage temperature ranging from 0℃ to 35℃.

3. The stacking height should not exceed two layers, and the upper and lower layers should be neatly stacked. It is not advisable to stack them in a staggered manner.

The validity period is 6 months under suitable storage conditions.