Product

Peroxide cross-linked semiconductive shielding material for cross-linked polyethylene insulated cabl

This product is mainly applicable to the cross-linked bonded semiconductive conductor shielding of 35kV cross-linked polyethylene insulated cables.

Product details

Product model and name:

PYJD-35    Peroxide cross-linked semiconductive shielding material for cross-linked polyethylene insulated cable conductors of 35kV and below

Performance indicators (typical values):               enforce standards JB/T 10738-2007

Serial number

Test project

Unit

Indicator 

PYJD-35

1

Density

g/cm3

≤1.2

1.11

2

Tensile strength

MPa

≥12

16

3

Elongation at break

%

≥180

260

4

Air thermal aging

Test conditions

/

135℃×168h

Rate of change of tensile strength

%

±30

+3

Rate of change in elongation at break

%

±30

-15

5

(-40℃)Impact embrittlement performance

Number of failures

≤15/30

0/30

6

Thermal extension

Test conditions

/

200℃×0.2MPa×15min

Elongation under load

%

≤100

65

Permanent deformation after cooling

%

≤15

0

7

Volume resistivity at 20℃

Ω.cm

≤100

40

8

Volume resistivity at 90℃

Ω.cm

≤5000

350

9

Volume resistivity after air thermal aging

Test conditions

/

100℃×168h

Volume resistivity at 90℃

Ω.cm

≤1000

350

Application process reference

It is recommended that the temperature of the extruder body be between 70℃ and 100℃. Neck temperature: 100℃ to 110℃ Head temperature: 110℃ to 115℃. It is recommended to use a 20× 60-mesh double-layer filter screen.

Packaging and storage

1) The product is packed in a waterproof and dustproof PE inner bag, supplemented by a hard corrugated carton for shaping and protection, and an additional waterproof film cover. The standard net weight of each box is 500kg or 600kg.

2) It should be stored in a clean, dry and well-ventilated environment, with an appropriate storage temperature ranging from 0℃ to 35℃.

3) The stacking height should not exceed two layers, and the upper and lower layers should be neatly stacked. It is not advisable to stack them in a staggered manner.

4) The validity period is 6 months under suitable storage conditions.

XML 地图