Product

Modified polypropylene insulating material for power cables of 10kV and below PJ-10

This product is mainly made of polypropylene resin through mixing, plasticizing and granulation. It is a non-cross-linked cable insulation material, mainly used for insulation of power cables of 10kV and below. Compared with the conventional cross-linked polyethylene cable insulation materials, it has its unique circular economy advantages.

Product details

Performance indicators (typical values):              enforce standards:T/SHPTA 014. 1 -2021

Serial number

Experimental project

Standard

Typical value

1

Appearance

It is in the form of 3x4mm round or shoulder-round particles, with uniform size and color, 

no coke particles, and no obvious powder substances

"Conforms to"

2

Volume resistivity(20℃)

≥1 × 1014  ( Ω·m)

2.4x1014

3

Volume resistivity(90℃)

≥3 × 101 1 ( Ω·m)

4.8x1011

4

Volume resistivity(105℃)

≥1 × 101 0 ( Ω·m)

2.1 × 1010

5

Dielectric loss Angle tangent(20 ° C51Hz)

≤1x10- 3

9.8× 10- 4

6

Dielectric strength(20℃)

≥35( MV/ m)

37

7

Tensile strength

≥13. 5 ( Mpa)

21.8

8

Elongation at break

≥350(%)

537

9

Density


0.875

10

Thermal deformation

≤40%

1.5

11

Low-temperature embrittlement temperature(-76℃)

≤15/ 30

0/ 30

12

Thermal aging

150℃168h

Rate of change of tensile strength

≤±25(%)

-16.8

Rate of change in elongation at break

≤±25(%)

-13.2

Application process reference

It is recommended that the temperature of the extruder body be between 160℃ and 200℃. Neck temperature: 200℃ Head temperature: 210℃ to 215℃.

Packaging and storage

The product is packed in a waterproof and dustproof PE inner bag, with a hard corrugated carton for shaping and protection, and an additional waterproof film cover. The standard net weight of each box is 500kg or 600kg.

It should be stored in a clean, dry and well-ventilated environment, with an appropriate storage temperature ranging from 0℃ to 35℃.

3. The stacking height should not exceed two layers, and the upper and lower layers should be neatly stacked. It is not advisable to stack them in a staggered manner.

The validity period is 6 months under suitable storage conditions.