Product

105 irradiation cross-linked insulating material TFWJ2600-05 for wire distribution, 105 degrees bund

This product is mainly applied to fabric wires with bundled A, B and C class combustion requirements. It features good extrusion fluidity and low carbonization height during combustion tests.

Product details

Product model and name:

TFWJ2600-05 105-degree irradiation cross-linked insulating material for fabric wires

Performance indicators (typical values) :           Execution standards: JB/T10491, GB/T18380

Serial number

Test project

Unit

Indicator

Typical value

1

Tensile strength

MPa

≥10

13

2

Elongation at break

%

≥150

165

3

Air thermal aging

Test conditions

135℃×168h

Maximum rate of change of tensile strength

%

±25

6

The maximum rate of change of elongation at break

%

±25

-5

4

Hardness

ShoreA

96±2

97

5

Volume resistivity at 20°C

Ω.m

≥1×1012

5×1012

6

(-25℃)lmpact embrittlement performance

Failures

≤15/30

0/30

7

Oxygen index

%

≥38

40

8

Combustion releases acidic gases

The contents of HCl and HBr

%

≤0.5

0

HF content

%

≤0.1

0

pH value

/

≥4.3

5

Electrical conductivity

μS/mm

≤10

1

9

Density

g/cm3

1.56±0.02

1.56

Application process reference

It is recommended that the temperature of the extruder body be 135 to 170℃. Head temperature: 170℃ to 175℃. It is recommended to use a low smoke zero halogen screw with a compression ratio of 1.2 to 1.6. The maximum melt temperature is suggested to be controlled within 185℃.

The product is packed in moisture-proof aluminum foil polyethylene composite film bags, 25kg per bag, and transported by single palletizing. The weight of each single pallet can be 1000kg or 1200kg.

It should be stored in a clean, dry and well-ventilated environment. The suitable storage temperature is 0℃ to 35℃.

The product is vacuum-packed. It is strictly prohibited to stack it up and down during transportation and storage. ,

The validity period is 6 months under suitable storage conditions.